Specification
| Built-in Communications | Modbus built-In |
| Control Type | V/f, Sensorless Vector, Close Loop Vector |
| Flow-chart logic programming | Yes |
| Mounting | Vertical Mount |
| Power Phase | 3-phase |
| Speed range | 0.01 - 400 Hz |
| Starting torque | 2 |
| Supply Voltage | 480 VAC |
| Power Phase | 3-phase |
| Constant Torque-Horsepower | 5 HP |
| Constant Torque-Current | 9.0 A |
Note: Select options by the maximum applicable motor capacity of heavy and light load rating.
dimension

software
| 3G3RX2-A2[][][][][] | A2004 | A2007 | A2015 | A2022 | A2037 | |||
|---|---|---|---|---|---|---|---|---|
| Applicable motor (4-pole) capacity (kW) |
VLD | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | ||
| LD | 0.75 | 1.5 | 2.2 | 3.7 | 5.5 | |||
| ND | 0.4 | 0.75 | 1.5 | 2.2 | 3.7 | |||
| Output | Rated output current (A) |
VLD | 4.4 | 8.0 | 10.4 | 15.6 | 22.8 | |
| LD | 3.7 | 6.3 | 9.4 | 12.0 | 19.6 | |||
| ND | 3.2 | 5.0 | 8.0 | 11.0 | 17.5 | |||
| Overload current rating |
VLD | 110% 60 sec / 120% 3 sec | ||||||
| LD | 120% 60 sec / 150% 3 sec | |||||||
| ND | 150% 60 sec / 200% 3 sec | |||||||
| Rated output voltage | 3-phase (3-wire) 200 to 240 V (depending on receiving voltage) | |||||||
| Rated capacity (kVA) |
200 V | VLD | 1.5 | 2.8 | 3.6 | 5.4 | 7.9 | |
| LD | 1.3 | 2.2 | 3.3 | 4.2 | 6.8 | |||
| ND | 1.1 | 1.7 | 2.8 | 3.8 | 6.1 | |||
| 240 V | VLD | 1.8 | 3.3 | 4.3 | 6.5 | 9.5 | ||
| LD | 1.5 | 2.6 | 3.9 | 5.0 | 8.1 | |||
| ND | 1.3 | 2.1 | 3.3 | 4.6 | 7.3 | |||
| Braking | Regenerative braking | Equipped with BRD circuit (with a discharging resistor separately installed) | ||||||
|---|---|---|---|---|---|---|---|---|
| Minimum resistance that can be connected (Ω) |
16 | 10 | 10 | 7.5 | 7.5 | |||
| Dimension | Height (mm) | 260 | 260 | 260 | 390 | 390 | ||
| Width (mm) | 210 | 210 | 210 | 245 | 245 | |||
| Depth (mm) | 170 | 170 | 170 | 190 | 190 | |||
| Protective construction | IP20 *5 / UL open type | |||||||
| Approximate mass (kg) | 6 | 6 | 6 | 10 | 10 | |||
| 3G3RX2-A2[][][][][] | A2220 | A2300 | A2370 | A2450 | A2550 | |||
|---|---|---|---|---|---|---|---|---|
| Applicable motor (4-pole) capacity (kW) |
VLD | 30 | 37 | 45 | 55 | 75 | ||
| LD | 30 | 37 | 45 | 55 | 75 | |||
| ND | 22 | 30 | 37 | 45 | 55 | |||
Note: For details, refer to the CX-One Catalog (Cat. No. R134), visit your local OMRON website.
Automation Software Sysmac Studio
built-in EMC filter
The RX2 Series with the same mounting dimension as the previous model will fit in the existing control panel or mounting location. In addition, the same setting software CX-Drive can be used for the RX2 Series. Parameter settings and programs used for the previous model can be easily converted and transferred to the RX2 Series.
Note: The depth of some models may vary.

Built-in EMC Filter
• Inverter: Select the model of your inverter. The table below assumes that your inverter is used in the heavy load mode and
connected to a single motor with the same capacity. Make sure that the approximate braking torque in the table
shows the assumed value per a motor with the same capacity at ND mode. When using this inverter at LD or VLD
mode, you need to calculate the torque value by dividing VLD by ND.
• Operating conditions: Show the torque during deceleration and the deceleration time (in % ED) calculated as a percentage
of the cycle time for 1 cycle of operation including the stop time.
• Braking unit/Breaking resistor: Show the required the model and number of units.
• Connection form: Show the configuration of the regenerative braking unit(s) and braking resistor(s) illustrated in the
connection form table below.
• Restrictions: Show the maximum deceleration time allowable for the combination shown here and the minimum resistance
that can be connected to the inverter's built-in regenerative braking circuit or external regenerative braking unit(s).
| Name | Specifications | Model |
|---|---|---|
| PG Option Unit | For Position or Frequency Control | 3G3AX-RX2-PG01 |
| Digital Operator Connecting Cable |
RJ45 connector, EIA568-compliant cable (UTP category 5), Cable Length 1 m | 3G3AX-OPCN1 |
| RJ45 connector, EIA568-compliant cable (UTP category 5), Cable Length 3 m | 3G3AX-OPCN3 |
Payment & dilivery
● Payment Methods:
Advised to make payment by T/T bank transfer.
Other options, like Alibaba Trade Insurance Invoice, and PayPal
● Shipping Ways:
Normally we do shipment with an express company like FedEx, DHL, UPS.
You can also go with your own freight forwarder if you have one here.
● Trade Terms: under EXW, shipped from Guangzhou, China


Hot Tags: omron inverter 3g3rx2-a4037,v/f, sensorless vector, close loop vector, suppliers, distributor, buy, price, discount, original, in stock, Mitsubishi PLC CPU Q06UDHCPU, MR J3 40B, Mitsubishi electric servo motor HF series, Automation Display Units GT1265 VNBA, AC Frequency converter, Mitsubishi 3 Phase 380V FR D740 1 5K CHT
Send Inquiry