Omron Inverter 3G3RX2-A4450,V/f, Sensorless Vector, Close Loop Vector
Part number:3G3RX2-A4450
Availability: In stock
Contact us: inquiry@lanenelectric.com
Product Introduction
Specification
| Built-in Communications | Modbus built-In |
| Control Type | V/f, Sensorless Vector, Close Loop Vector |
| Flow-chart logic programming | Yes |
| Mounting | Vertical Mount |
| Power Phase | 3-phase |
| Speed range | 0.01 - 400 Hz |
| Starting torque | 2 |
| Supply Voltage | 480 VAC |
| Power Phase | 3-phase |
| Constant Torque-Horsepower | 60 HP |
| Constant Torque-Current | 91 A |
Note: Select options by the maximum applicable motor capacity of heavy and light load rating.
related options
The RX2 Series features Safe Torque Off (STO) as standard to meet your machine safety needs.
・STO according to IEC 61800-5-2:2016
・PLe and CAT 4 according to EN ISO 13849-1:2015
・SIL3 according to IEC 61508:2010 and EN/IEC 62061:2012

software
| Input terminal function | 11 terminals (input of pulse string is available on terminal A and B) | ||
|---|---|---|---|
| FW (Normal rotation)/RV (Reverse rotation), CF1-4 (Multistage speed 1-4), SF1-7 (Multistage speed bit 1-7), ADD (Addition of frequency), SCHG (Switching of frequency command), STA (3-wire start)/STP (3-wire stop)/F_R (3-wire normal/ reverse), AHD (Retention of analog command), FUP (Increase of speed via remote operation/FDN (Deceleration via remote operation), UDC (Deletion of data via remote operation), F-OP (Forced command switching), SET (Second control), RS (Reset), JG (Jogging), DB (External current braking), 2CH (2-stage acceleration/deceleration), FRS (Free-run stop), EXT (External abnormality), USP (Prevention of restart after restoration of power), CS (Commercial switching), SFT (Soft-lock), BOK (Brake check), OLR (Overload restriction switching), KHC (Clearance of integrated input power), OKHC (Clearance of integrated output power), PID (PID1 disabled), PIDC (PID1 integration reset), PID2 (PID2 disabled), PIDC2 (PID2 integration reset), SVC1-4 (PID1 multistage target values 1-4), PRO (PID gain switching), PIO (PID output switching), SLEP (SLEEP condition satisfied)/WAKE (WAKE condition satisfied), TL (Torque restriction enabled), TRQ1, 2 (Switching of torque limit 1, 2), PPI (Switching of P/PI control), CAS (Switching of control gain), FOC (Preparatory excitation), ATR (Torque control enabled), TBS (Torque bias enabled), LAC (Cancellation of acceleration/ deceleration), Mi1-11 (General-purpose input 1-11), PCC (Clearance of pulse counter), ECOM (Start of EzCOM), PRG (Program run), HLD (Acceleration/ deceleration stop), REN (Operation permission signal), PLA (Pulse string input A), and PLB (Pulse string input B) |
Automation Software Sysmac Studio
Payment & dilivery
● Trade Terms: EXW Guangzhou, China
Mitsubishi RJ71DN91 Network Module DeviceNet Communication Module R Series
● Payment Methods:
√ Accepted Payment Currency: USD, CNY
Mitsubishi RJ71DN91 Network Module DeviceNet Communication Module R Series


fAQ
-
1.Q: Which payment form you can accept?
A: T/T, Ali-pay etc.
Siemens Industry SIPLUS RIC library for SIMATIC S7-300 6AG6003-1CF01-0DA0 SIPLUS RIC for SIMATIC S7-3xx MMC 2MB
2.Q: What is your term of payment?
A: 50% down payment before producing and 50% balance payment before shipping.
Siemens Industry SIPLUS RIC library for SIMATIC S7-300 6AG6003-1CF01-0DA0 SIPLUS RIC for SIMATIC S7-3xx MMC 2MB
3.Q:What's the delivery time ?
A: About 4-12 daysSiemens Industry SIPLUS RIC library for SIMATIC S7-300 6AG6003-1CF01-0DA0 SIPLUS RIC for SIMATIC S7-3xx MMC 2MB
4. Q:How many warranty days could you provide ?
A: Most of our products with one year warranty time from the EXW delivery date.
Siemens Industry SIPLUS RIC library for SIMATIC S7-300 6AG6003-1CF01-0DA0 SIPLUS
Hot Tags: omron inverter 3g3rx2-a4450,v/f, sensorless vector, close loop vector, suppliers, distributor, buy, price, discount, original, in stock
Send Inquiry


