OMRON E2B-M12KN08-WP-B1 2M Sensor: Inductive; OUT: PNP / NO; 0÷8mm; 10÷30VDC; M12; IP67; 200mA
Part number:OMRON E2B-M12KN08-WP-B1 2M
Availability:Sensor: inductive; OUT: PNP / NO; 0÷8mm; 10÷30VDC; M12; IP67; 200mA
Contact us: inquiry@lanenelectric.com
Product Introduction
|
Product Specifications |
|
Manufacturer |
OMRON | |
|
Type of sensor |
inductive | |
|
Output configuration |
PNP / NO | |
|
Range |
0...8mm | |
|
Switch housing |
M12 | |
|
Connection |
lead 2m | |
|
IP rating |
IP67 | |
|
Max. operating current |
0.2A | |
|
Operating temperature |
-25...70°C | |
|
Kind of forehead |
non-embedded | |
|
Body material |
brass | |
|
Switching frequency max |
800Hz | |
|
Overall length |
47mm | |
|
Body plating |
nickel |
Perfect fit for standard environments • Embody two seemingly contradictory characteristics: value-formoney and high reliability • All 372 Models • Four different sizes: M8, M12, M18 and M30 • Single and double sensing distances, Shielded and unshielded • A choice of short and long bodies, two connecting methods and four output types • Operating temperature: –25ºC to 70ºC • Water resistance: IP67 • With an all-round 360º visible indicator.
High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its waterresistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. Precautions continued Type M8 Stainless steel type Brass type M12 M18 M30 Torque 9 N·m 4 N·m 30 N·m 70 N·m 180 N·m

High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its waterresistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. Precautions continued Type M8 Stainless steel type Brass type M12 M18 M30 Torque 9 N·m 4 N·m 30 N·m 70 N·m 180 N·m
| Type of sensor | inductive |
| Body material | stainless steel |
| Supply voltage | 12...24V DC |
| Max. operating current | 200mA |
| IP rating | IP67 |
| Operating temperature | -40...70°C |
Size Type Item Sensing distance Setting distance Hysteresis Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control output Indicator Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence (See note 2.) Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standards and listings Connection method Weight (packaged) Material Pre-wired model M12 connector model Case Sensing surface Cable Clamping nut Load current (See note 2.) Residual voltage Shielded E2A-M18S08--B1 E2A-M18S08--B2 E2A-M18S08--C1 E2A-M18S08--C2 8 mm ±10% 0 to 6.4 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 10 mA max. -B models: PNP open collector -C models: NPN open collector 200 mA max. (32 VDC max.) 2 V max. (under load current of 200 mA with cable length of 2 m) Operation indicator (Yellow LED) -B1/-C1 models: NO -B2/-C2 models: NC; For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation) ±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C Operating: 35% to 95%, Storage: 35% to 95% ±1% max. of sensing distance in rated voltage range ±15% 50 MΩ min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 1,000 m/s2 , 10 times each in X, Y and Z directions IEC60529: IP67, Degree of protection EN60947-5-2: EMC UL (CSA) [E196555] (See note 3.) -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g Brass-nickel plated PBT PVC Brass-nickel plated M18 M30 Unshielded E2A-M18N16--B1 E2A-M18N16--B2 E2A-M18N16--C1 E2A-M18N16--C2 16 mm ±10% 0 to 12.8 mm Shielded E2A-M30S15--B1 E2A-M30S15--B2 E2A-M30S15--C1 E2A-M30S15--C2 15 mm ±10% 0 to 12 mm Unshielded E2A-M30KN20--B1 E2A-M30KN20--B2 E2A-M30KN20--C1 E2A-M30KN20--C2 20 mm ±10% 0 to 16 mm Unshielded E2A-M30LN30--B1 E2A-M30LN30--B2 E2A-M30LN30--C1 E2A-M30LN30--C2 30 mm ±10% 0 to 24 mm 24 x 24 x 1 mm 500 Hz 48 x 48 x 1 mm 400 Hz 45 x 45 x 1 mm 250 Hz 60 x 60 x 1 mm 100 Hz 90 x 90 x 1 mm 100 Hz DC 3-wire Models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max. 3. UL (CSA) [E196555]: Use class 2 circuit only.

Size Type Item Sensing distance Setting distance Hysteresis Target Standard target (mild steel ST37) Response frequency (See note 1.) Power supply voltage (operating voltage range) Current consumption (DC 3-wire) Output type Control output Indicator Operation mode (with sensing object approaching) Protection circuit Ambient air temperature Temperature influence (See note 2.) Ambient humidity Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Standards and listings Connection method Weight (packaged) Material Pre-wired model M12 connector model Case Sensing surface Cable Clamping nut Load current (See note 2.) Residual voltage Shielded E2A-M18S08--B1 E2A-M18S08--B2 E2A-M18S08--C1 E2A-M18S08--C2 8 mm ±10% 0 to 6.4 mm 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal.) 12 to 24 VDC. Ripple (p-p): 10% max. (10 to 32 VDC) 10 mA max. -B models: PNP open collector -C models: NPN open collector 200 mA max. (32 VDC max.) 2 V max. (under load current of 200 mA with cable length of 2 m) Operation indicator (Yellow LED) -B1/-C1 models: NO -B2/-C2 models: NC; For details, refer to the timing charts. Output reverse polarity protection, Power source circuit reverse polarity protection, Surge suppressor, Short-circuit protection Operating: -40°C to 70°C, Storage: -40°C to 85°C (with no icing or condensation) ±10% max. of sensing distance at 23°C within temperature range of -25°C to 70°C ±15% max. of sensing distance at 23°C within temperature range of -40°C to 70°C Operating: 35% to 95%, Storage: 35% to 95% ±1% max. of sensing distance in rated voltage range ±15% 50 MΩ min. (at 500 VDC) between current carry parts and case 1,000 VAC at 50/60 Hz for 1 min between current carry parts and case 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y and Z directions 1,000 m/s2 , 10 times each in X, Y and Z directions IEC60529: IP67, Degree of protection EN60947-5-2: EMC UL (CSA) [E196555] (See note 3.) -WP models: Pre-wired models (Standard length: 2 m) -M1 models: M12 4-pin connector models -M5 models: M8 3-pin connector models Approx. 160 g Approx. 280 g Approx. 280 g Approx. 370 g Approx. 70 g Approx. 200 g Approx. 200 g Approx. 260 g Brass-nickel plated PBT PVC Brass-nickel plated M18 M30 Unshielded E2A-M18N16--B1 E2A-M18N16--B2 E2A-M18N16--C1 E2A-M18N16--C2 16 mm ±10% 0 to 12.8 mm Shielded E2A-M30S15--B1 E2A-M30S15--B2 E2A-M30S15--C1 E2A-M30S15--C2 15 mm ±10% 0 to 12 mm Unshielded E2A-M30KN20--B1 E2A-M30KN20--B2 E2A-M30KN20--C1 E2A-M30KN20--C2 20 mm ±10% 0 to 16 mm Unshielded E2A-M30LN30--B1 E2A-M30LN30--B2 E2A-M30LN30--C1 E2A-M30LN30--C2 30 mm ±10% 0 to 24 mm 24 x 24 x 1 mm 500 Hz 48 x 48 x 1 mm 400 Hz 45 x 45 x 1 mm 250 Hz 60 x 60 x 1 mm 100 Hz 90 x 90 x 1 mm 100 Hz DC 3-wire Models Note 1. The response frequency is an average value. Measurement conditions are as follows: standard target, a distance of twice the standard target distance between targets, and a setting distance of half the sensing distance. 2. When using any model at an ambient temperature between -40°C and -25°C and a power voltage between 30 and 32 VDC, use a load current of 100 mA max. 3. UL (CSA) [E196555]: Use class 2 circuit only.Perfect fit for standard environments • Embody two seemingly contradictory characteristics: value-formoney and high reliability • All 372 Models • Four different sizes: M8, M12, M18 and M30 • Single and double sensing distances, Shielded and unshielded • A choice of short and long bodies, two connecting methods and four output types • Operating temperature: –25ºC to 70ºC • Water resistance: IP67 • With an all-round 360º visible indicator.

High-tension Lines Wiring through Metal Conduit: If there is a power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunctioning. Cable Extension Standard cable length is less than 200 m. The tractive force is 50 N. Mounting The Proximity Sensor must not be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its waterresistivity. Do not tighten the nut with excessive force. A washer must be used with the nut. Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. 1. Check for mounting position, dislocation, looseness, or distortion of the Proximity Sensor and sensing objects. 2. Check for loose wiring and connections, improper contacts, and line breakage. 3. Check for attachment or accumulation of metal powder or dust. 4. Check for abnormal temperature conditions and other environmental conditions. 5. Check for proper lighting of indicators (for models with a set indicator.) Never disassemble or repair the Sensor. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors, or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e.g., strong alkaline or acid gasses including nitric, chromic, and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e.g., a lamp or motor) will damage the Proximity Sensor, in which case connect the load to the Proximity Sensor through a relay. Precautions continued Type M8 Stainless steel type Brass type M12 M18 M30 Torque 9 N·m 4 N·m 30 N·m 70 N·m 180 N·m

|
Related Products |

E2B-S08KN04-WP-C2 2MOMRON
E2B 2 Ordering Information Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. Material specifications for stainless steel housing case: 1.4305 (W.-No.), SUS 303 (AISI), 2346 (SS). Note: 1. Pre-wired Models are available in the cable lengths of 2 m and 5 m. 2. There are restrictions that apply to Shielded sensors. Please refer to "Effects of Surrounding Metal" on page 20. Size Sensing distance Connecting method (See note 1.) Body length Output configuration Operation mode NO Operation mode NC M8 (Stainless steel) (See note 2.) Single Shielded Pre-wired Short PNP E2B-S08KS01-WP-B1 2M E2B-S08KS01-WP-B2 2M NPN E2B-S08KS01-WP-C1 2M E2B-S08KS01-WP-C2 2M Long PNP E2B-S08LS01-WP-B1 2M E2B-S08LS01-WP-B2 2M NPN E2B-S08LS01-WP-C1 2M E2B-S08LS01-WP-C2 2M M8 Connector (3-pin) Short PNP E2B-S08KS01-MC-B1 E2B-S08KS01-MC-B2 NPN E2B-S08KS01-MC-C1 E2B-S08KS01-MC-C2 Long PNP E2B-S08LS01-MC-B1 E2B-S08LS01-MC-B2 NPN E2B-S08LS01-MC-C1 E2B-S08LS01-MC-C2 Unshielded Pre-wired Short PNP E2B-S08KN02-WP-B1 2M E2B-S08KN02-WP-B2 2M NPN E2B-S08KN02-WP-C1 2M E2B-S08KN02-WP-C2 2M Long PNP E2B-S08LN02-WP-B1 2M E2B-S08LN02-WP-B2 2M NPN E2B-S08LN02-WP-C1 2M E2B-S08LN02-WP-C2 2M M8 Connector (3-pin) Short PNP E2B-S08KN02-MC-B1 E2B-S08KN02-MC-B2 NPN E2B-S08KN02-MC-C1 E2B-S08KN02-MC-C2 Long PNP E2B-S08LN02-MC-B1 E2B-S08LN02-MC-B2 NPN E2B-S08LN02-MC-C1 E2B-S08LN02-MC-C2 Double Shielded Pre-wired Short PNP E2B-S08KS02-WP-B1 2M E2B-S08KS02-WP-B2 2M NPN E2B-S08KS02-WP-C1 2M E2B-S08KS02-WP-C2 2M Long PNP E2B-S08LS02-WP-B1 2M E2B-S08LS02-WP-B2 2M NPN E2B-S08LS02-WP-C1 2M E2B-S08LS02-WP-C2 2M M8 Connector (3-pin) Short PNP E2B-S08KS02-MC-B1 E2B-S08KS02-MC-B2 NPN E2B-S08KS02-MC-C1 E2B-S08KS02-MC-C2 Long PNP E2B-S08LS02-MC-B1 E2B-S08LS02-MC-B2 NPN E2B-S08LS02-MC-C1 E2B-S08LS02-MC-C2 Unshielded Pre-wired Short PNP E2B-S08KN04-WP-B1 2M E2B-S08KN04-WP-B2 2M NPN E2B-S08KN04-WP-C1 2M E2B-S08KN04-WP-C2 2M Long PNP E2B-S08LN04-WP-B1 2M E2B-S08LN04-WP-B2 2M NPN E2B-S08LN04-WP-C1 2M E2B-S08LN04-WP-C2 2M M8 Connector (3-pin) Short PNP E2B-S08KN04-MC-B1 E2B-S08KN04-MC-B2 NPN E2B-S08KN04-MC-C1 E2B-S08KN04-MC-C2 Long PNP E2B-S08LN04-MC-B1 E2B-S08LN04-MC-B2 NPN E2B-S08LN04-MC-C1 E2B-S08LN04-MC-C2
| Payment & Delivery |
● Payment Methods:
√ Accepted Payment Currency: USD, CNY
√ Accepted Payment Type: TT Bank transferetc.
● Shipping Ways:
√ DHL/FedEx/UPS for fast and Door-to-Door shipment.
√ By Air+ delivery or by Sea+delivery for bulk of batch goods.
√ Customer can specify freight forwarders or other shipping Methods.

| Our Service |
● Price Advantage
We enjoy a mature industrial chain and convenient access to major transportation networks. Thus we ensure give the most competitive prices to customers and guarantee the completion time.
● Professional Service Team
Strong professional sales team in service any time. we are sure any of your inquiry will get our prompt attention & reply in 1-4 hours. If there's any question, please contact with our sales.
● Large Stock and High Efficiency
Our company have large stock which keep more than 10 thousands products in Guangzhou and Hongkong warehouses. We usually ship the items within 1-5 working days after the payment is reached.

| FAQ |
1.Q: Which payment form you can accept?
A: T/T, Ali-pay etc. We accept any convenient and swift payment term.
2.Q: What is your term of payment?
A: 30% down payment before producing and 70% balance payment before shipping.
3.Q:What's the delivery time ?
A: The general delivery time for semi auto machines is 3-7 days after receiving your prepayment of the order; 25-30 days for the full auto machines. If we have the goods in stock, it will only take 1-3 days.
Hot Tags: omron e2b-m12kn08-wp-b1 2m sensor: inductive; out: pnp / no; 0÷8mm; 10÷30vdc; m12; ip67; 200ma, suppliers, distributor, buy, price, discount, original, in stock
Send Inquiry